IMC Networks iMediaChassis/6 User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
20
Power Supply Modules
Power supply modules in all models of the iMediaChassis/3 are fixed, and not end-
user replaceable.
Fans
The iMediaChassis/3 includes temperature-triggered fans. When the temperature of
the chassis reaches 40° C, the two fans activate to cool the chassis. The fans
operation can be tested by holding the Reset Alarm Switch down for 4 to 5 seconds.
The fans will activate and then they will turn off when the button is released. If the
fans do not activate, contact IMC Networks. Fans are not end-user replaceable.
The red Alarm Reset Switch also functions as a Fan Test button. To verify fan
functionality, hold the button down for several seconds, the fans should engage. The
fans will turn off when the button is released.
iMediaChassis/3 Specifications
Input Specifications
Dual AC Input: 90 to 264 VAC, 47-440Hz
AC Inrush Current: <60A Peak @230VAC
AC Input Power: <74W
Dual DC Input: 35 to 75VDC
DC Input Current: 2.7A maximum @35VDC, Full Load
Operating Temperature:
AC: 0° C to 50° C (32° F to 122° F)
DC: -40° C to 100° C (-67° F to 257° F)
Storage Temperature:
AC: -40° C to 85° C (-40° F to 185° F)
DC: -55° C to 125° C (-40° F to 212° F)
Humidity: 5 to 90% (non-condensing); 0 to 10,000 ft. altitude
Shipping Weight: 5 lbs (2.3 kg)
Dimensions: H=1.73” W=7.50” D=8.74” (4.4 x 19.0 x 22.0 cm)
Page view 23